To check the bowl speed on a running purifier, you typically use a tachometer or a digital speed sensor. First, ensure that the purifier is operating at its normal speed, then position the tachometer near the rotating bowl to measure its RPM. Some purifiers also have built-in speed indicators that can be monitored on the control panel. Always follow safety protocols to avoid any accidents while performing this check.
check valve inlet and outlet open fresh water start feed pump open heating start the bowl after the ampere is going down and steady start the purifier in auto
1. purifier bowl 2. gravity disc 3. disc stacks 4. pump 5. pairing discs 6.Teflon seals
1. purifier bowl 2. gravity disc 3. disc stacks 4. pump 5. pairing discs 6.Teflon seals
1. purifier bowl 2. gravity disc 3. disc stacks 4. pump 5. pairing discs 6.Teflon seals
The bowl spindle cone in an oil purifier serves to stabilize and support the rotating bowl during the separation process. It helps maintain the correct alignment and minimizes vibrations, ensuring efficient separation of impurities from the oil. Additionally, the cone facilitates the movement of separated contaminants to the discharge outlet, enhancing the overall performance of the oil purification system.
check that the toilet stopper has been switched on and check that the strainer inside the toilet inlet is clear of debris
The function of Lock ring or lock nut in the purifier is basically to the parts in the purifier together.As the lock ring is tightened the bowl is compressed ,in turn compressing the disc stack.The disc stack pressure is very important and the lock ring should never be overtightened. The lock ring usually has a left hand thread if the purifier turns clockwise as vice versa to prevent it from slackening during operation.
yes
Overhoul of any purifier in spite of its trade mark must be carried out in strict accordance to its manual book.See anex maintanence Here is a basic steps: 1.Purifier should be complitly stoped. 2.Aply a bowl brack if such exists. 3.Remove F.W. inlet and the nut under it in order to release upper cover from the bowl.See anex tools. 4.Lift the upper cover and secure it. 5.Loose the locking ring of gravity disc and than locking ring of a bowl with ccording tools.Pay attention to the marks on a locking ring and the edge of a bowl.Loosening direction is clockwise. 6.Remove the bowl cover and then Bowl inner parts are available for you to clean them.
Larry Csonka in Super Bowl VIII
Super Bowl 50 ad prices were running as high as $5,000,000 per 30 second ad.
1