Because it is induced
No, the forced draft fan has positive pressure as it just forces yhe air into the combustion chamber.only the induced draft fan has negative pressureas it removes the flue gases & exhaust gases is stacked up
In a balanced draft boiler, you actually have both: forced draft (FD) fans supplying air to the furnace, and induced draft (ID) fans removing flue gas. Typically, the FD fans control airflow, while ID Fans control furnace pressure to slightly below atmospheric pressure. In general though, the choice between forced draft and induced draft is based on how "tight" the system is - if you have leaks, it is better to use ID, as FD will cause product loss.
During the defrost cycle of a forced draft low temperature evaporator, the evaporator fan would typically be turned off to prevent warm air from interfering with the defrost process and to help the coil achieve proper defrosting temperatures.
The pressure at the discharge side of a forced draft fan is generally higher than the surrounding atmospheric pressure due to the fan's action of pushing air into a system. This pressure level can vary depending on the design of the fan and the requirements of the system it is serving. It is typically measured in inches of water gauge (in wg) or pascals (Pa).
The procedure for starting draft plant (fans) in a boiler is to start the ID Fan first. Remember that the purpose of the ID Fan is so that the Furnace operates at a slight vacuum. (See Related Link: FD Fan vs ID Fan.) Any casing or furnace leaks then allow air to leak in, rather than allowing air with pulverised fuel and fly ask to leak out.
Induced draft --- A mechanical draft tower with a fan at the discharge (at the top) which pulls air up through the tower. The fan induces hot moist air out the discharge. This produces low entering and high exiting air velocities, reducing the possibility of recirculation in which discharged air flows back into the air intake. This fan/fin arrangement is also known as draw-through. (see Image 3)Forced draft --- A mechanical draft tower with a blower type fan at the intake. The fan forces air into the tower, creating high entering and low exiting air velocities. The low exiting velocity is much more susceptible to recirculation. With the fan on the air intake, the fan is more susceptible to complications due to freezing conditions. Another disadvantage is that a forced draft design typically requires more motor horsepower than an equivalent induced draft design. The benefit of the forced draft design is its ability to work with high static pressure. Such setups can be installed in more-confined spaces and even in some indoor situations. This fan/fill geometry is also known as blow-through.
A forced draught is where the air flow comes directly from the fan to the object. Such as an hair dryer.An induced draught is where the air flow is induced {lit lead in} by a separate flow of air. For example, an abrasive jet would quickly wear out if the abrasive passed through the jet nozzle. the flow of abrasive is added (induced) into the air flow by a jet of clean air.If an air flow is corrosive or very dirty then an induced flow system would be appropriate.
The Draft.
The main difference between an ID (Induced Draft) fan and a FD (Forced Draft) fan lies in their placement in a system. An ID fan is located after the furnace or boiler and helps to draw waste gases out of the system, while an FD fan is positioned before the furnace or boiler to supply fresh air into the system for combustion. ID fans create negative pressure, while FD fans create positive pressure within the system.
It forced the realization that the Articles of Confederation were unworkable, and a Convention was called to draft the Constitution.
It can be used, however not on the same piece of equipment. A forced draft fan is typically much smaller than an induced draft fan. A FD fan moves cooler air into the combustion zone while the ID fan removes the products of combustion from that zone. Typically the volume of gasses the ID Fan needs to remove is from 125% to 200% more than that of the FD fan. example: an FD fan moves 20,000 scfm of air at 100 *F, what size ID fan do you need if the exhaust gasses are 450 *F and the products of combustion and moisture add 3500 cfm to the volume of gasses? PV/T = P'V'/T' with pressure being negligible (it usually isn't) the formula is then : V/T = V'/T' to get the volume needed for the ID fan then: VT'/T = V' V = 20,000 scfm, T = 560 *R (absolute zero scale) and T' = 910 *R 20,000 scfm x 910*R/560*R = 20,000 scfm x 1.625 = 32,500 scfm thus, the ID fan must be sized at least 62.5% larger than the FD fan.